WhatsApp +65 9389 9198

E2S

WARNING SIGNALS · INDUSTRIAL + HAZARDOUS AREAS

Be heard.Be seen.Be understood.

Sounders and beacons for factories, marine installations and hazardous areas.

D1xB2X05 · red and amber lens variants
In focusD1xB2X05 · red and amber lens variants
About E2S

Warning devices for demanding environments

You can choose E2S sounders and beacons to suit your site’s noise levels, lighting and environment. The range includes industrial, marine and explosion-protected models, with different voltages, tones and lens colours.

Meet the manufacturer
Our products

The E2S range

D1xB2X05 · red and amber lens variants
Product guide

Read the code. Understand the beacon.

Explore selected fields in the D1xB2X05 ordering code. This guide covers one product family, not every E2S part number.

D1xB2X05DC024MB1A1RR

See how enclosure and lens colours change the D1xB2X05 code. The manufacturer’s configurator includes all ordering options.

Red enclosure · Red lens

24 V DC · 5 J xenon · A version. Red or clear lens is required for the manufacturer’s cited EN 54-23 / MED configuration.

What do the other fields mean?
D1xB2
Product family
X05
5 J xenon
DC024
24 V DC
M
Manufacturer's default cable-entry arrangement
B
Brass plug / adaptor material
1
316 stainless-steel guard
A
Product approval version A
1
Standard product option
View manufacturer guidance
A closer look

A lens colour changes more than the look

Audible and visual warning in industrial facilities
Audible and visual warning in industrial facilities
01

Visibility

Lens colour and light output affect how far a beacon can be seen.

02

Audibility

Sounder tone and volume determine how clearly an alarm stands out from background noise.

03

Location

Hazardous-area ratings identify the gas or dust environments and temperatures a device is designed for.

Certifications

Approvals, at a glance

The D1xB2X05 EN 54-23 / MED option is the 24 V DC A version with a red or clear lens. Other versions carry different approvals.

Applications

Where And How To Use The Range

Oil and gas
Oil and gas
Chemical processing
Chemical processing
Marine and offshore
Marine and offshore
ManufacturingMiningCommercial fire alarm

Specialist Applications

Intrinsically Safe Controls

The GNExCP7-PB-I call point provides intrinsically safe manual activation; its published specification includes SIL 2 compliance.

Manufacturer Details
Flameproof Warning Devices

BEx and STEx ranges include flameproof warning devices. Select the enclosure, gas or dust rating and temperature range for the installation.

Manufacturer Details
From the Manufacturer

Watch & Explore

E2S Warning Signals Introduction English

Technical resources

Product documents and downloads

More technical guidance for E2S

Product selection

  • Required approval and hazardous-area marking
  • Sound output, tone and current
  • Flash output, colour and pattern
  • Voltage, enclosure, ingress and mounting

How the products work

  • Ordinary-location, marine and explosion-protected ranges must not be treated as interchangeable even when their output appears similar.
  • Selection needs both audibility and visual coverage calculations, not only the maximum headline dB or candela value.
  • Hazardous-area products require the complete gas/dust group, temperature class, zone or division and ambient range to match.
Frequently asked questions

Quick answers

Can I decode any E2S part number here?

You can use this guide to understand selected fields in a D1xB2X05 part number. If you have a different family or an older code, send it to us and we can help you identify it.

Is any red beacon a fire alarm visual device?

No. A red lens doesn’t tell you whether a beacon has the fire-alarm approval or coverage you need. You’ll need a model and configuration listed for that use.

Can I substitute a different supply voltage?

No. Your device’s marked voltage and electrical load, including its starting current, need to match the circuit. We can help you find the right voltage variant.

What do I need to specify for an E2S sounder?

Provide the background noise, listening distance, alarm tone, power supply and installation location. The maximum sound rating alone does not show whether people will hear it throughout the area.

Which E2S model can be used in a hazardous area?

Choose by the area classification and the exact certificate, including gas or dust group, temperature and ambient limits. An explosion-protection marking does not make a device suitable for every location.

What should I send when replacing an E2S device?

Send a clear photograph of the complete nameplate, part number, supply voltage and cable entries. Include the required tone or beacon colour and the installation environment.

Talk To Our Team

Make the warning unmistakable

Share the location classification, supply voltage and coverage requirement.

Send An Enquiry
Business enquiry

Find the right team

We normally respond within one business day. Use WhatsApp or telephone for urgent support.

Your information is used only to respond and route this enquiry.